  • 发布时间: 2018 - 05 - 21
    技术参数:○ 流速范围:0.001~10.000mL/min○ 流速准确度:±0.5%○ 最大耐压:9000 PSI○ 压力脉动:≤1%○ 控温范围:室温+5℃~70℃○ 温度准确度:±1.0%○ 温度稳定性:±0.1%○ 进样重复性:RSD≤0.3%○ 交叉污染:○ 线性:0.9999○ 采样率:100Hz
    RIGOL L-3000 Quaternary Auto sampling,With the design of UPLC, the maximum pressure resistance is up to 9000psi. It is the liquid chromatography system with the highest pressure range in the same kind of instrument. The flow range is wide to 10mL/min, and its application field is extended from the conventional liquid phase to the fast liquid phase. The instrument has complete independent intellectual property rights, and its core parts are designed and manufactured independently. It can be widely used in pharmaceutical analysis, environmental monitoring, food safety, petrochemical industry, ag...
  • 发布时间: 2018 - 05 - 21
    ○ 流速范围:0.001~10.000mL/min○ 流速准确度:±0.5%○ 最大耐压:9000 PSI○ 压力脉动:≤1%○ 控温范围:室温+5℃~70℃○ 温度准确度:±1.0%○ 温度稳定性:±0.1%○ 进样重复性:RSD≤0.3%○ 交叉污染:○ 线性:0.9999○ 采样率:100Hz○ 光源:高效LED 470nm
    RIGOL L-3000高效液相色谱系统采用UPLC规格设计,最高耐压达9000psi,是同类仪器中耐压范围最高的液相色谱系统,流量范围宽至10mL/min,将其应用领域从常规液相拓展到快速液相。该款仪器具有完全自主知识产权,关键核心部分均为自主设计、加工制造。可广泛应用于药物分析、环境监测、食品安全、石油化工、农林牧渔、教育科研等各个领域。
  • 发布时间: 2018 - 05 - 21
    ○ 流速范围:0.001~10.000mL/min○ 流速准确度:±0.5%○ 最大耐压:9000 PSI○ 压力脉动:≤1%○ 控温范围:室温+5℃~70℃○ 温度准确度:±1.0%○ 温度稳定性:±0.1%○ 进样重复性:RSD≤0.3%○ 交叉污染:○ 线性:0.9999○ 采样率:100Hz○ 阵列数:1024阵列
    RIGOL L-3000高效液相色谱系统采用UPLC规格设计,最高耐压达9000psi,是同类仪器中耐压范围最高的液相色谱系统,流量范围宽至10mL/min,将其应用领域从常规液相拓展到快速液相。该款仪器具有完全自主知识产权,关键核心部分均为自主设计、加工制造。可广泛应用于药物分析、环境监测、食品安全、石油化工、农林牧渔、教育科研等各个领域。
  • 发布时间: 2018 - 05 - 21
    ○ 流速范围:0.001~10.000mL/min○ 流速准确度:±0.5%○ 最大耐压:9000 PSI○ 压力脉动:≤1%○ 控温范围:室温+5℃~70℃○ 温度准确度:±1.0%○ 温度稳定性:±0.1%○ 进样重复性:RSD≤0.3%○ 交叉污染:○ 线性:0.9999○ 采样率:100Hz
    RIGOL L-3000高效液相色谱系统采用UPLC规格设计,最高耐压达9000psi,是同类仪器中耐压范围最高的液相色谱系统,流量范围宽至10mL/min,将其应用领域从常规液相拓展到快速液相。该款仪器具有完全自主知识产权,关键核心部分均为自主设计、加工制造。可广泛应用于药物分析、环境监测、食品安全、石油化工、农林牧渔、教育科研等各个领域。
  • 发布时间: 2018 - 05 - 21
    ○ 流速范围:0.001~10.000mL/min○ 流速准确度:±0.5%○ 最大耐压:9000 PSI○ 压力脉动:≤1%○ 控温范围:室温+5℃~70℃○ 温度准确度:±1.0%○ 温度稳定性:±0.1%○ 采样率:100Hz
    RIGOL L-3000高效液相色谱系统采用UPLC规格设计,最高耐压达9000psi,是同类仪器中耐压范围最高的液相色谱系统,流量范围宽至10mL/min,将其应用领域从常规液相拓展到快速液相。该款仪器具有完全自主知识产权,关键核心部分均为自主设计、加工制造。可广泛应用于药物分析、环境监测、食品安全、石油化工、农林牧渔、教育科研等各个领域。
Contact information

Phone: 86-010-58629061

Cell phone: 18515336778

Mailbox:contact@aidphe.com

China · Beijing · Changping

Contact address:China Beijing Changping Wanjia Pioneering Park Zone B

Determination of Eight Artificial Colorants in Food

Date: 2018-06-05
Views: 113
案例名称: Determination of Eight Artificial Colorants in Food

Artificial synthetic colorants, also known as synthetic pigments, are usually made from benzene, toluene and other raw materials by first preparing pigment intermediates, then sulfonating, coupling, condensation and azo reaction of one or two intermediates. 'Determination of synthetic colorants in food' (GB/T 5009.35-2003), polyamide was used to adsorb synthetic colorants in food and eluted with ethanolamine solution. The adsorption capacity of polyamide to synthetic pigments will be affected by temperature. Samples and eluents need to be heated in the experiment, and ethanolamine concentration takes too long. This method is not suitable for simultaneous treatment of large quantities of samples and is not easy to be transplanted by automated methods. Most synthetic colorants have the structure of sodium benzenesulfonate. RIGOL-3000 liquid chromatography system was used to detect them, which meets the requirements of national standards and is suitable for simultaneous detection of large quantities of samples.

The operation steps include: 2.1, reagent solvent preparation; 2.2, standard working curve preparation; 2.3, sample pretreatment; 2.4, chromatographic analysis; 2.5, data processing.

Laboratory environmental requirements:

Operating ambient temperature:   20-30 C

Relative humidity:   20%-80%

Fire Protection:   Have Fire Protection Equipment

Ventilation:   Good ventilation environment

Location:   away from high electromagnetic interference and high vibration equipment

Solvent Compatibility:   Solvent Compatibility with Structural Materials


Electrical Indicators:


Power supply voltage:   100 VACRMS - 240 VACRMS

Voltage frequency:   50 Hz - 60 Hz



More details can be downloaded by clicking on the file below. Thank you.

食品中八种人工着色剂的测定食品中八种人工着色剂的测定.pdf

Related solutions Solution / More >
2018 - 06 - 05
点击次数: 135
According to the first method of high performance liquid chromatography in GB/T 22388-2008 Method for the Detection of Melamine in Raw Milk and Dairy Products, a certain amount of homogeneous raw milk...
2018 - 06 - 05
点击次数: 120
The contents of 17 amino acids, glycine, leucine, methionine, tyrosine, histidine, threonine, alanine, isoleucine, tryptophan, cystine, lysine, aspartic acid, arginine, phenylalanine, proline, glutami...
2018 - 06 - 05
点击次数: 283
Amino acid analysis is an important auxiliary method for the determination of nitrogen content and protein content in feed. With the development of reversed-phase chromatography technology, the determ...
2018 - 06 - 05
点击次数: 125
According to the content determination method of preservatives in 'Hygienic Code for Cosmetics (2007 Edition)', a certain amount of uniform cosmetics (hereinafter referred to as samples) were weighed,...
2018 - 06 - 05
点击次数: 113
Artificial synthetic colorants, also known as synthetic pigments, are usually made from benzene, toluene and other raw materials by first preparing pigment intermediates, then sulfonating, coupling, c...
2018 - 06 - 05
点击次数: 17
On October 22, 2012, the Ministry of Agriculture announced in its announcement No. 1849 'Licensing Conditions for Feed Manufacturing Enterprises' and 'Licensing Conditions for Mixed Feed Additives Man...
WeChat
Copyright ©2008 - 2018 Aidefei Technology (Beijing) Co., Ltd. Sitemap 粤ICP备09063742号-1
Rhino Cloud provides enterprise cloud services
犀牛云提供云计算服务